Variable_order Dataset_name Variable_name Variable_label Type Codelist Role Core CDISC_notes
1 EG STUDYID Study Identifier Char Identifier Req Unique identifier for a study.
2 EG DOMAIN Domain Abbreviation Char Identifier Req Two-character abbreviation for the domain.
3 EG USUBJID Unique Subject Identifier Char Identifier Req Identifier used to uniquely identify a subject across all studies for all applications or submissions involving the product.
4 EG SPDEVID Sponsor Device Identifier Char Identifier Perm Sponsor-defined identifier for a device.
5 EG EGSEQ Sequence Number Num Identifier Req Sequence number given to ensure uniqueness of subject records within a domain. May be any valid number.
6 EG EGGRPID Group ID Char Identifier Perm Used to tie together a block of related records in a single domain for a subject.
7 EG EGREFID ECG Reference ID Char Identifier Perm Internal or external ECG identifier. Example: "UUID".
8 EG EGSPID Sponsor-Defined Identifier Char Identifier Perm Sponsor-defined reference number. Perhaps preprinted on the CRF as an explicit line identifier or defined in the sponsor's operational database. Example: Line number from the ECG page.
9 EG EGTESTCD ECG Test or Examination Short Name Char C71153
C120523
Topic Req Short name of the measurement, test, or examination described in EGTEST. It can be used as a column name when converting a dataset from a vertical to a horizontal format. The value in EGTESTCD cannot be longer than 8 characters, nor can it start with a number (e.g., "1TEST" is not valid). EGTESTCD cannot contain characters other than letters, numbers, or underscores. Examples : "PRAG", "QRSAG". Test codes are in two separate codelists, one for tests based on regular 10-second ECGs (EGTESTCD) and one for tests based on Holter monitoring (HETESTCD).
10 EG EGTEST ECG Test or Examination Name Char C71152
C120524
Synonym Qualifier Req Verbatim name of the test or examination used to obtain the measurement or finding. The value in EGTEST cannot be longer than 40 characters. Examples: "PR Interval, Aggregate", "QRS Duration, Aggregate". Test names are in two separate codelists, one for tests based on regular 10-second ECGs (EGTEST) and one for tests based on Holter monitoring (HETEST).
11 EG EGCAT Category for ECG Char Grouping Qualifier Perm Used to categorize ECG observations across subjects. Examples: "MEASUREMENT", "FINDING", "INTERVAL".
12 EG EGSCAT Subcategory for ECG Char Grouping Qualifier Perm A further categorization of the ECG.
13 EG EGPOS ECG Position of Subject Char C71148 Record Qualifier Perm Position of the subject during a measurement or examination. Examples: "SUPINE", "STANDING", "SITTING".
14 EG EGBEATNO ECG Beat Number Num Variable Qualifier Perm A sequence number that identifies the beat within an ECG.
15 EG EGORRES Result or Finding in Original Units Char Result Qualifier Exp Result of the ECG measurement or finding as originally received or collected. Examples of expected values are "62" or "0.151" when the result is an interval or measurement, or "ATRIAL FIBRILLATION" or "QT PROLONGATION" when the result is a finding.
16 EG EGORRESU Original Units Char C71620 Variable Qualifier Perm Original units in which the data were collected. The unit for EGORRES. Examples: "sec" or "msec".
17 EG EGSTRESC Character Result/Finding in Std Format Char C120522
C71150
Result Qualifier Exp Contains the result value for all findings, copied or derived from EGORRES in a standard format or standard units. EGSTRESC should store all results or findings in character format; if results are numeric, they should also be stored in numeric format in EGSTRESN. For example, if a test has results of "NONE", "NEG", and "NEGATIVE" in EGORRES and these results effectively have the same meaning, they could be represented in standard format in EGSTRESC as "NEGATIVE". For other examples, see general assumptions. Additional examples of result data: "SINUS BRADYCARDIA", "ATRIAL FLUTTER", "ATRIAL FIBRILLATION". Test results are in two separate codelists, one for tests based on regular 10-second ECGs (EGSTRESC) and one for tests based on Holter monitoring (HESTRESC).
18 EG EGSTRESN Numeric Result/Finding in Standard Units Num Result Qualifier Perm Used for continuous or numeric results or findings in standard format; copied in numeric format from EGSTRESC. EGSTRESN should store all numeric test results or findings.
19 EG EGSTRESU Standard Units Char C71620 Variable Qualifier Perm Standardized units used for EGSTRESC and EGSTRESN.
20 EG EGSTAT Completion Status Char C66789 Record Qualifier Perm Used to indicate an ECG was not done, or an ECG measurement was not taken. Should be null if a result exists in EGORRES.
21 EG EGREASND Reason ECG Not Done Char Record Qualifier Perm Describes why a measurement or test was not performed. Examples: "BROKEN EQUIPMENT" or "SUBJECT REFUSED". Used in conjunction with EGSTAT when value is "NOT DONE".
22 EG EGXFN ECG External File Path Char Record Qualifier Perm File name and path for the external ECG waveform file.
23 EG EGNAM Vendor Name Char Record Qualifier Perm Name or identifier of the laboratory or vendor who provided the test results.
24 EG EGMETHOD Method of Test or Examination Char C71151 Record Qualifier Perm Method of the ECG test. Example: "12 LEAD STANDARD".
25 EG EGLEAD Lead Location Used for Measurement Char C90013 Record Qualifier Perm The lead used for the measurement. Examples: "LEAD 1", "LEAD 2", "LEAD 3", "LEAD rV2", "LEAD V1".
26 EG EGLOBXFL Last Observation Before Exposure Flag Char C66742 Record Qualifier Exp Operationally-derived indicator used to identify the last non-missing value prior to RFXSTDTC. The value should be "Y" or null.
27 EG EGBLFL Baseline Flag Char C66742 Record Qualifier Perm Indicator used to identify a baseline value. Should be "Y" or null. Note that EGBLFL is retained for backward compatibility. The authoritative baseline for statistical analysis is in an ADaM dataset.
28 EG EGDRVFL Derived Flag Char C66742 Record Qualifier Perm Used to indicate a derived record. The value should be "Y" or null. Records that represent the average of other records, or that do not come from the CRF, or are not as originally collected or received are examples of records that would be derived for the submission datasets. If EGDRVFL = "Y", then EGORRES could be null, with EGSTRESC and EGSTRESN (if the result is numeric) having the derived value.
29 EG EGEVAL Evaluator Char C78735 Record Qualifier Perm Role of the person who provided the evaluation. Used only for results that are subjective (e.g., assigned by a person or a group). Should be null for records that contain collected or derived data. Examples: "INVESTIGATOR", "ADJUDICATION COMMITTEE", "VENDOR".
30 EG EGEVALID Evaluator Identifier Char C96777 Variable Qualifier Perm Used to distinguish multiple evaluators with the same role recorded in EGEVAL. Examples: "RADIOLOGIST 1" or "RADIOLOGIST 2".
31 EG EGREPNUM Repetition Number Num Record Qualifier Perm The incidence number of a test that is repeated within a given timeframe for the same test. The level of granularity can vary, e.g., within a time point or within a visit. For example, multiple measurements of blood pressure or multiple analyses of a sample.
32 EG VISITNUM Visit Number Num Timing Exp 1. Clinical encounter number. 2. Numeric version of VISIT, used for sorting.
33 EG VISIT Visit Name Char Timing Perm 1. Protocol-defined description of clinical encounter. 2. May be used in addition to VISITNUM and/or VISITDY.
34 EG VISITDY Planned Study Day of Visit Num Timing Perm Planned study day of the visit based upon RFSTDTC in Demographics.
35 EG TAETORD Planned Order of Element within Arm Num Timing Perm Number that gives the planned order of the Element within the Arm for the element in which the assessment was made.
36 EG EPOCH Epoch Char C99079 Timing Perm Epoch associated with the date/time at which the assessment was made.
37 EG EGDTC Date/Time of ECG Char ISO 8601 Timing Exp Date/Time of ECG.
38 EG EGDY Study Day of ECG Num Timing Perm 1. Study day of the ECG, measured as integer days. 2. Algorithm for calculations must be relative to the sponsor-defined RFSTDTC variable in Demographics.
39 EG EGTPT Planned Time Point Name Char Timing Perm 1. Text description of time when measurement should be taken. 2. This may be represented as an elapsed time relative to a fixed reference point, such as time of last dose. See EGTPTNUM and EGTPTREF. Examples: "Start", "5 min post".
40 EG EGTPTNUM Planned Time Point Number Num Timing Perm Numerical version of EGTPT to aid in sorting.
41 EG EGELTM Planned Elapsed Time from Time Point Ref Char ISO 8601 Timing Perm Planned elapsed time (in ISO 8601) relative to a fixed time point reference (EGTPTREF). Not a clock time or a date time variable. Represented as an ISO 8601 duration. Examples: "-PT15M" to represent the period of 15 minutes prior to the reference point indicated by EGTPTREF, or "PT8H" to represent the period of 8 hours after the reference point indicated by EGTPTREF.
42 EG EGTPTREF Time Point Reference Char Timing Perm Name of the fixed reference point referred to by EGELTM, EGTPTNUM, and EGTPT. Examples: "PREVIOUS DOSE", "PREVIOUS MEAL".
43 EG EGRFTDTC Date/Time of Reference Time Point Char ISO 8601 Timing Perm Date/time for a fixed reference time point defined by EGTPTREF.